- Quality of the measurement data is medium.
- Origin of the data is Fulcrum Acoustic.
- Format of the data is a GLL file .
-
Sensitivity:
- Company: 89 dB
- Measured: 96.8 dB (avg. 300Hz-3kHz for 2.83V estimated at 1m).
- Measured: 76.8 dB computed at the measurement distance (10.0m) over the same frequency range.
- -3dB (resp. -6db) point v.s. reference is at 109.0Hz (resp. 100.0Hz).
- Reference level is normalised to -0.1dB computed over the frequency range [300.0Hz, 5000.0Hz].
- Frequency deviation is 1.4dB over the same frequency range.
- Tonality (Preference) Score
- Tonality (Preference) Score is 3.24
and would be 6.8 with a
perfect subwoofer.
- Details: NBD: ON 0.443, LW 0.406, SP 0.519, PIR 0.451; SM: SP0.826, PIR0.68; LFQ 1.206, LFX 97Hz
- Tonality (Preference) Score is 3.86
with an EQ and would be 7.38 with a
perfect subwoofer and the same EQ.
- Details: NBD: ON 0.447, LW 0.375, SP 0.446, PIR 0.389; SM: SP0.93, PIR0.854; LFQ 1.026, LFX 95Hz
- Tonality (Preference) Score is 3.24
and would be 6.8 with a